Sorption-Caused Attenuation and Delay of Water Vapor Signals in Eddy-Covariance Sampling Tubes and Filters

2014 
AbstractAdsorption and desorption (together called sorption) processes in sampling tubes and filters of eddy-covariance stations cause attenuation and delay of water vapor signals, leading to an underestimation of water vapor fluxes by tens of percent. The aim of this work was (i) to quantify the effects on sorption in filters and tubes of humidity, flow rate, and dirtiness and (ii) to test a recently introduced sorption model that facilitates correction of fluxes. Laboratory measurements on the transport of water vapor pulses through tubes and filters were carried out, and eddy-covariance field measurements were also used.In the laboratory measurements, the effects of sorption processes were evident, and filters caused a similar attenuation and delay of the signal as tubes. Filters could have a larger impact than a long tube, whereas the flow rate had a much smaller impact on the flux loss than the sorption processes (Reynolds numbers 2120–3360). The sorption model represented well the water vapor pulses...