RELATING DOSE OUTSIDE THE PROSTATE WITH FREEDOM FROM FAILURE IN THE DUTCH TRIAL 68 GY VS. 78 GY

2010 
Purpose For prostate cancer patients at risk for subclinical spread of the disease, we investigated whether incidental dose outside the target was associated with tumor control. Methods and Materials We selected 352 intermediate-risk (mainly T2b-T3a) and high-risk (mainly T3b) patients treated in a randomized trial. Target volume was prostate (68–78 Gy) and seminal vesicles (50–78 Gy). Failure (clinical or biochemical) was evaluated at 4 years. To compare three-dimensional dose distributions, an automated mapping procedure was introduced. Between patients, these maps provide an approximate identification of corresponding anatomical locations. Maps of the dose difference between patients with and without failure were constructed. Univariate and multivariate analyses were performed including the dose in selected points. Results Dose differences were mainly found in the obturatorial region for the high-risk patients, and in the presacral region for the intermediate risk group (>7 Gy, p p = 0.01, obturatorial) and 0.72 ( p = 0.002, presacral). These hazard ratios were stable under multivariate analysis correcting for established prognostic factors, hospital, and dose to the prostate. Conclusions Patients without failure have received on average a higher dose to regions where regional cancer spread could be expected.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    11
    References
    35
    Citations
    NaN
    KQI
    []