2019 
ABSTRACTBackground: The objective of this study (ClinicalTrials.gov ID: NCT03031015) is to compare the treatments of hand proximal phalanx shaft fractures with external-fixation technique using the combination of K-wires and bone-cement vs. open reduction and internal fixation technique using a miniature plate-and-screw system.Methods: A total of 107 patients (134 cases) were randomly allocated to group A (67 cases in 56 patients) and B (64 cases in 51 patients). Fingers in group A were treated with bone-cement K-wire fixation, and fingers in group B were treated using a plate-and-screw system.Results: Follow-ups lasted 2 years. In group A, active range of motion of proximal interphalangeal joint reached 93% ± 6.7% of the opposite fingers. In group B, the data reached 86% ± 14.4% of the opposite fingers. Based on total active motion scoring system, we obtained 21 excellent and 46 good results in group A; and 9 excellent, 50 good, and 5 fair results in group B. There was a significant difference with regar...