CFD and Experimental Analysis of a Falling Film outside Smooth and Helically Grooved Tubes

2014 
Ansys Fluent 14.” The three-dimensional model drawings in the x, y ,a ndz coordinates are used, and the effects of the falling film outside the helically grooved tube on the surface temperature and surface heat transfer coefficient are determined. The average surface temperature, heat transfer coefficient, and Nu values are determined experimentally for a constant heat flux. An uncertainty analysis and Nu correlation for the grooved tube are also provided in this study.The Reynolds number varied between 50 and 350 for the falling film and between 1500 and 3500 for air. Using a computational fluid dynamics (CFD) analysis for the reference smooth tube, the experimental results are validated within 2–12% difference. The experimental results are also within 6–13% of the grooved tubes.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    18
    References
    3
    Citations
    NaN