Intermediate Dynamic Compression and Decreased Posterior Tilt with Interlocked Pins in Femoral Neck Fixation in Synthetic Bone.

2021 
Fixation failure with resulting nonunion is the key complication after femoral neck fixation. It can be avoided by permitting dynamic compression and reducing rotation and posterior tilt of the femoral head. To achieve this, a novel implant that features an interlocking plate with 3 hook-pins (The Hansson Pinloc? System) was developed from the original 2 hook-pins. Only an enhanced torsional fixation by the implant modification is reported. The purpose was to compare the biomechanical compressive and bending stability of the original and modified implant in femoral neck fixation. To analyse the contribution of both modified components, 3 individual pins were included, although not in regular use. Forty-eight synthetic femurs with midcervical wedge osteotomies were fixated by 2 pins or identical triangular pin patterns with or without the plate. Eight specimens of each group were loaded cyclically in compression with an inferior wedge to simulate stance and anteroposterior bending with a posterior wedge to imitate sitting down. The clinically relevant stability measurements were stiffness and deformation. Fissure formation defined failure. The novel implant improved bending stability by 30% increased stiffness, 44% reduced deformation and less frequent posterior neck fissure formation (p < 0.001). Increased compressive stability were only evident with 25% reduced deformation and less frequent inferior neck fissures (p < 0.001). These impacts were mainly mediated by the 3rd pin, while the plate prevented a lateral fissure in compression (p < 0.001). The clinical stability was improved by dynamic compression and decreased posterior tilt by implant modification.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    33
    References
    0
    Citations
    NaN
    KQI
    []