Effects of Time Delay Between Unipolar Pulses in High Frequency Nano-Electrochemotherapy.

2021 
This work focuses on bleomycin electrochemotherapy using new modality of high repetition frequency unipolar nanosecond pulses. As a tumor model, Lewis lung carcinoma (LLC1) cell line in C57BL mice (n = 42) was used. Electrochemotherapy was performed with intertumoral injection of bleomycin (50 L of 1500 IU solution) followed by nanosecond and microsecond range electrical pulse delivery via parallel plate electrodes. The 3.5 kV/cm pulses of 200 and 700 ns were delivered in a burst of 200 at frequencies of 1 kHz and 1 MHz. For comparison of treatment efficiency, a standard 1.3 kV/cm x 100 s x 8 protocol was used. It was shown that it is possible to manipulate the efficacy of unipolar sub-microsecond electrochemotherapy solely by the time delay between the pulses. Also, the results suggest that the sub-microsecond range pulses can be as effective as the protocols in European Standard Operating Procedures on Electrochemotherapy (ESOPE) using 100 s pulses.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []