Day at the Races: Comparing BioFire FilmArray Blood Culture ID Panels to Verigene Blood Culture in Gram-negative Bloodstream Infections using DOOR-MAT Analysis.
2021
Three RDT platforms (Verigene BC-GN, BioFire® BCID, and BCID 2 (RUO)) were compared using the Desirability of Outcome Ranking Management of Antimicrobial Therapy (DOOR -MAT) to evaluate potential downstream antimicrobial prescribing decisions resulting from the panels different organism and resistance detection. BioFire BCID (RUO) had the best mean DOOR-MAT scores.