Soft x-ray and bolometric tomography in RFX
1997
The article presents the design and the first results of a new eight camera, soft x-ray (SXR) and bolometric tomography which has been installed in RFX, a large (R=2 m, a=0.46 m), high current reverse field pinch experiment operating in Padova. The main features of the diagnostic, which has been designed with standards compatible with the requirements of large fusion experiments, are: (a) it allows simultaneous reconstruction of both SXR and total radiation emissivity structures with high spatial and time resolution (bandwidth up to 200 kHz for SXR and 10 kHz for bolometry). Moreover, computer controlled remote actions which interchange up to five material filters in front of the detectors allow the exploration of different energy ranges; (b) it can be easily decoupled from the machine without breaking the main vacuum and can be operated during first wall baking up to 300 °C thanks to a cooling circuit; (c) the detection chain is designed to measure very low signals [in the order of 1 nA for SXR diodes an...
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
6
References
22
Citations
NaN
KQI