Radiographic Change in Articular Reduction After Volar Locking Plating for Intra-Articular Distal Radius Fractures
2019
Purpose To examine the stability of the articular reduction 12 weeks after intra-articular distal radius fracture (DRF) fixation with a volar locking plate (VLP). Methods We prospectively assessed for losses in articular reduction, including gap and step, during the 12 weeks following surgery for intra-articular DRF treated with a VLP in 68 wrists. The mean patient age was 62 years (range, 16–88 years). Frontal and lateral digital tomosynthesis, a recently developed form of digital tomography, was employed to measure articular gap and step in the lunate and scaphoid fossa of the radius. The average time between surgery and imaging was 1.2 days (range, 0–2 days) for the first evaluation and 87.0 days (range, 74–105 days) for the second examination. Results The mean gap and step were similar at the first and second examinations: 0.4 mm (SD, 0.8) and 0.3 mm (SD, 0.6) and 0.3 mm (SD, 0.7) and 0.3 mm (SD, 0.5), respectively. Conclusions There was no change in the alignment of the fragments in cases treated with VLP. Type of study/level of evidence Therapeutic II.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
22
References
1
Citations
NaN
KQI