Localization and quantification of trace-gas fugitive emissions using a portable optical spectrometer

2018 
We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν 3 R(4) CH 4 transition at 6057.1 cm -1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv·Hz- 1/2 , corresponding to a noise-equivalent absorbance (NEA) of 4.4×10 -6 Hz -1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10 -7 cm -1 ·Hz -1/2 . Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH 4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-ofarrival (AOA) results will be shown, and development towards source magnitude estimation will be described.