Heartbeat assessment in infants: a comparison of four clinical methods.

2005 
Objective: To compare the performance of four clinical methods (apex ear auscultation; brachial, carotid, and femoral pulse palpation) for detecting and counting heart beat in infants. Design: Cross-sectional, repeated-measures study design. Prospective data collection. Setting: A postanesthesia care unit of a pediatric teaching hospital in Italy. Patients: Fifty-six normotensive sedated infants, aged 1–12 mos, were evaluated by 14 pediatric basic life support (PBLS)-qualified health professionals. Interventions: None. Measurements and Main Results: The proportion of successful heartbeat detections ranged from 60% with carotid pulse palpation to 98% with apex auscultation. Among successful detections, apex auscultation proved to be the most rapid way to detect heart rate (median, 4 secs) and the most accurate with a median discrepancy of 8 beats/min (vs. 12 with the other methods) from the electrocardiographic results. Differences between apex auscultation and pulse palpation were statistically significant (p Conclusions: Apex listening is the most successful, rapid, and accurate method to detect and count the heartbeat by PBLS-certified professionals in normotensive infants without instruments. Pulse checking remains important for assessing the effectiveness of circulation. Palpating the brachial, carotid, or femoral pulse is equally effective.