Motion artifact control in body MR imaging.

1999 
: The mechanisms involved in the generation of motion artifacts in MR imaging are complex and depend both on the type and direction of motion as well as on the parameters of the imaging sequence chosen. The methods used to control or reduce motion artifacts are multiple and the appropriate method for use with any given clinical situation will depend on the particular hardware and software of the MR imaging unit, the patient's clinical status, and the specific organ or disease state to be imaged. Some general guidelines for clinical use that are applicable in most scenarios can be defined, although preferences for the different techniques vary. Appropriate T1-weighted images of the upper abdomen and liver can be obtained with breath-hold T1-weighted gradient echo. These images should be acquired with inferior-superior spatial presaturation pulses to reduce vascular pulsation artifact and ghosting. The application of GMN will depend on the individual MR imaging system. If sufficient coverage cannot be obtained with gradient-echo imaging, then conventional T1-weighted images with phase-encoding reordering is suggested. The addition of spatial presaturation pulses (inferior-superior) may be valuable. The use of fat suppression will further improve image quality by reducing ghost artifact and improving CNR, although SNR will decrease. T2-weighted imaging of the upper abdomen will depend greatly on the hardware and software of the MR imaging unit. Recent techniques of breath-hold T2-weighted imaging require faster and stronger gradients, and may not be universally available. If available, these techniques provide excellent anatomic detail, although image contrast (e.g., liver to spleen) may decrease. Respiratory-triggered FSE techniques are the preferred method of imaging in most centers, because the imaging time is considerably less than conventional T2-weighted imaging whereas the image quality is improved. Liver lesion detection capability of the various techniques is still under study. The addition of fat suppression appears to improve image quality further with an increase in lesion detection. By understanding the principles underlying motion artifacts, one can choose the appropriate method of artifact control tailored for the individual clinical situation. In addition, the recognition of the variable appearances of motion artifacts will prevent interpretive errors and misdiagnoses. Careful attention to motion artifact reduction techniques can greatly improve patient care.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    13
    References
    29
    Citations
    NaN
    KQI
    []