Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure.
2020
OBJECTIVES: To evaluate short patent ductus arteriosus (TC-PDA) closure in small infants, specifically device-related left pulmonary artery (LPA) stenosis and aortic coarctation, risk factors, and changes over time. BACKGROUND: Recent studies have demonstrated successful transcatheter PDA (TC-PDA) closure in small infants. LPA stenosis and aortic coarctation have been seen after TC-PDA, but it is not clear whether device-related LPA/aortic obstruction persists. METHODS: A single-center retrospective study of infants /=1.5 m/s), which improved or resolved in all patients with available follow-up; 3 developed mild coarctation (>2 m/s), which improved in the two with more than short-term follow-up; 4 developed mild flow acceleration (1.5-2 m/s) in the descending aorta, which resolved in three and increased in one (2.4 m/s). Flow acceleration in the LPA was associated with younger procedural age, larger PDA minimal diameter, and placement of a device other than the AVPII. There was no device-related mortality or need for reintervention. CONCLUSION: TC-PDA in small infants is effective, without significant complications. Device-related LPA/aortic obstruction can improve with time/growth.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
30
References
8
Citations
NaN
KQI