Rate, Timing, Correlates, and Outcomes of Hemodynamic Valve Deterioration After Bioprosthetic Surgical Aortic Valve Replacement

2018 
Background: The incidence of structural valve deterioration after bioprosthesis (BP) aortic valve replacement (AVR) established on the basis of reoperation may substantially underestimate the true incidence. The objective is to determine the rate, timing, correlates, and association between hemodynamic valve deterioration (HVD) and outcomes assessed by Doppler echocardiography after surgical BP AVR. Methods: A total of 1387 patients (62.2% male, 70.5±7.8 years of age) who underwent BP AVR were included in this retrospective study. Baseline echocardiography was performed at a median time of 4.1 (1.3–6.5) months after AVR. All patients had an echocardiographic follow-up ≥2 years after AVR (926 at least 5 years and 385 at least 10 years). HVD was defined by Doppler assessment as a ≥10 mm Hg increase in mean gradient or worsening of transprosthetic regurgitation ≥1/3 class. HVD was classified according to the timing after AVR: “very early,” during the first 2-years; “early,” between 2 and 5 years; “midterm,” ...