Análisis de la implantación de prácticas seguras en los sistemas automatizados de dispensación de medicamentos

2013 
Objective: To determine the degree of implementation of recommended safety practices in the design and use of automated medication dispensing cabinets (ADCs) in Spanish hospitals. Methods: A descriptive study based on completion of the “SelfEvaluation Survey on the Safety of Automated Medication Dispensing Systems” from 10/10/2012 to 4/10/2013, at voluntarily participating hospitals. The survey contained 93 items grouped into 14 core processes. Results: In the 36 participating hospitals the average score for the completed survey was 307.8 points (66.2% of the highest possible score [LC 95% CI: 63.2-69.2]). The lowest scores were obtained for core processes 9, 12, 13, 8, 3, 4 and 11 referring to the establishment of guidelines for medication removed using the override function (28.4%), training for healthcare professionals (52%), risk management (53%), defining removal procedures (55.3%), use of ADCs in connection with electronic prescribing (60.9%), information that appears on ADC screens (61.8%) and eliminating medications being returned to ADCs (63.9%), respectively. The hospitals that used ADCs in connection with electronic prescribing as their principal system for distribution presented a higher level of implantation of safety practices than those that used ADCs as a complementary distribution system.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    11
    References
    7
    Citations
    NaN
    KQI
    []