Semi-scale Experiments For Model CalibrationAnd Verification In Water And Heat Transport InPorous Media

2005 
A semi-scale device is employed for monitoring the drying out process of a building envelope consisting of freshly cast gypsum elements and exterior thermal insulation in the conditions of difference climate. The climatic chamber system includes two climatic chambers connected by a specially developed tunnel for testing large specimens. As for the climatic conditions on the exterior side, the test reference year data for Prague are used. Constant temperature and relative humidity is assumed on the interior side. For monitoring moisture content, the time-domain reflectometry probes are used, for the relative humidity and temperature measurements capacitance sensors are utilized. The measurements are performed for the time period of 92 days. On the basis of the measured data, calibration of the computer code Delphin 4.4.16 is done. The measured values of temperature, relative humidity and moisture content are compared with the calculated data, and a fitting procedure is employed for the identification of model parameters that are not known with a sufficient accuracy.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    2
    References
    0
    Citations
    NaN
    KQI
    []