Apparent Diffusion Coefficient Measurement in Mediastinal Lymphadenopathies: Differentiation between Benign and Malignant Lesions

2017 
Objectives: We aimed to prospectively assess the diagnostic value of apparent diffusion coefficient (ADC) measurement in the differentiation of benign and malignant mediastinal lymphadenopathies. Materials and Methods: The study included 63 consecutive patients (28 women, 35 men; mean age 59.3 years) with 125 mediastinal lymphadenopathies. Echoplanar diffusion-weighted magnetic resonance imaging of the mediastinum was performed with b-factors of 0 and 600 mm 2 /s before mediastinoscopy and mediastinotomy, and ADC values were measured. The ADC values were compared with the histological results, and statistical analysis was done. P Results: The mean ADC value of malignant mediastinal lymphadenopathy (1.030 ± 0.245 × 10 −3 mm 2 /s) was significantly lower ( P −3 mm 2 /s). For differentiating malignant from benign mediastinal lymphadenopathy, the best result was obtained when an ADC value of 1.334 × 10 −3 mm 2 /s was used as a threshold value; area under the curve 0.848, accuracy 78.4%, sensitivity 66%, specificity of 86%, positive predictive value 76.7%, and negative predictive value of 79.2%. Interobserver agreement was excellent for ADC measurements. Conclusions: ADC measurements could be considered an important supportive method in differentiating benign from malignant mediastinal lymphadenopathies.