A Novel Thermoresponsive Gel as a Potential Delivery System for Lipoxin

2019 
The objective of this study was to evaluate a novel thermoresponsive polyisocyanopeptide (PIC)–based hydrogel as an injectable carrier for local drug delivery for periodontal applications. Three formulations of PIC gels, 0.2%, 0.5%, and 1% w/w, were prepared. As controls, commercially available poloxamer 407 (P407) gels of 20% and 26% w/w were used. Lipoxin A4 (LXA4), a proresolving drug, was suspended into the gel solutions. The systems were evaluated regarding dynamic mechanical properties, injectability and stability, release and bioactivity of LXA4, and cytocompatibility. Results showed that the gelation temperatures of PIC and P407 gels were around 13°C to 23°C. PIC gels were less viscous and mechanically weaker than P407 gels due to the low polymer concentrations. However, PIC gels kept gel integrity for at least 2 wk when incubated with phosphate-buffered saline, whereas P407 gels were disintegrated totally within 1 wk. LXA4 was chemically stable in both neutral and alkaline medium for over 1 mo. T...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    38
    References
    9
    Citations
    NaN
    KQI
    []