Performance Analysis of a Small-Scale ORC Trigeneration System Powered by the Combustion of Olive Pomace
2019
The utilisation of low- and medium-temperature energy allows to reduce the energy shortage and environmental pollution problems because low-grade energy is plentiful in nature and renewable as well. In the past two decades, thanks to its feasibility and reliability, the organic Rankine cycle (ORC) has received great attention. The present work is focused on a small-scale (7.5 kW nominal electric power) combined cooling, heating and power ORC system powered by the combustion of olive pomace obtained as a by-product in the olive oil production process from an olive farm situated in the central part of Italy. The analysis of the employment of this energy system is based on experimental data and Aspen Plus simulation, including biomass and combustion tests, biomass availability and energy production analysis, Combined Cooling Heat and Power (CCHP) system sizing and assessment. Different low environmental impact working fluids and various operative process parameters were investigated. Olive pomace has been demonstrated to be suitable for the energy application and, in this case, to be able to satisfy the energy consumption of the same olive farm with the option of responding to further energy users. Global electrical efficiency varied from 12.7% to 19.4%, depending on the organic fluid used and the working pressure at the steam generator.