i-gel: a new supraglottic device for effective resuscitation of a very low birthweight infant with Cornelia de Lange syndrome
2015
Laryngeal Mask Airway (LMA) has been indicated as an effective device for airway management when face-mask ventilation and intubation have both failed in infants weighing >2000 g or delivered ≥34 weeks of gestation. All previous studies used a classic LMA. The current report describes the first case of a very low birthweight infant (1470 g, +3 gestational weeks) with micrognathia and palate cleft with Cornelia De Lange syndrome, resuscitated at birth with a new supraglottic airway device, i-gel size-1, positioned by a trainee paediatrician at first attempt. The procedure allowed reaching prompt effective ventilation and oxygenation of the patient, who was stabilised and intubated through i-gel.