BEAM DIAGNOSTICS FOR THE NSLS-II BOOSTER

2011 
For successful commissioning and effective operation of the projected NSLS-II Booster, a set of beam diagnostic instruments has been designed. Fluorescent screens are used for the Booster commissioning and troubleshooting. Closed orbit is measured using electrostatic BPMs with turn-by-turn capability. The circulating current and beam lifetime are measured using a DC current transformer. The fill pattern is monitored by a fast current transformer. Visible synchrotron radiation is registered for observation of the beam image. Betatron tunes are measured using two pairs of striplines, the first pair is for beam excitation and the second one – for beam response measurement. Design and performance of the Booster beam instrumentation are described.