Hyperpolarized Gas Diffusion MRI of Biphasic Lung Inflation in Short and Long Term Emphysema Models
2017
During lung inflation, airspace dimensions are affected nonlinearly by both alveolar expansion and recruitment, potentially confounding the identification of emphysematous lung by hyperpolarized helium-3 diffusion magnetic resonance imaging (HP MRI). This study aimed to characterize lung inflation over a broad range of inflation volume and pressure values in two different models of emphysema, as well as in normal lungs. Elastase-treated rats (n = 7) and healthy controls (n = 7) were imaged with HP MRI. Gradual inflation was achieved by incremental changes to both inflation volume and airway pressure. The apparent diffusion coefficient (ADC) was measured at each level of inflation and fitted to the corresponding airway pressures as the second-order response equation, with minimizing residue (χ2 18 cmH2O. Discrimination between treated and control rats was optimal when airway pressure was...
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
36
References
4
Citations
NaN
KQI