Microwave- and Heat-Based Decontamination of N95 Filtering Facepiece Respirators: A Systematic Review.
2020
Abstract Background In pandemics such as COVID-19, shortages of personal protective equipment are common. One solution may be to decontaminate equipment such as facemasks for reuse. Aim To collect and synthesize existing information on decontamination of N95 filtering facepiece respirators (FFRs) using microwave and heat-based treatments, with special attention to impact on mask function (aerosol penetration, airflow resistance), fit, and physical traits. Methods A systematic review (PROSPERO CRD42020177036) of literature available from Medline, Embase, Global Health, and other sources was conducted. Records were screened independently by two reviewers, and data was extracted from studies that reported on effects of microwave- or heat-based decontamination on N95 FFR performance, fit, physical traits, and/or reductions in microbial load. Findings Thirteen studies were included that used dry/moist microwave irradiation, heat, or autoclaving. All treatment types reduced pathogen load by a log10 reduction factor of at least three when applied for sufficient duration (>30s microwave, >60 min dry heat), with most studies assessing viral pathogens. Mask function (aerosol penetration Conclusions Microwave irradiation and heat may be safe and effective viral decontamination options for N95 FFR reuse during critical shortages. The evidence does not support autoclaving or high-heat (>90oC) approaches. Physical degradation may be an issue for certain mask models, and more real-world evidence on fit is needed.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
49
References
18
Citations
NaN
KQI