MRI-based Preplanning Using CT and MRI Data Fusion in Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility and Accuracy Study

2011 
Purpose Magnetic resonance imaging (MRI)-assisted radiation treatment planning enables enhanced target contouring. The purpose of this study is to analyze the feasibility and accuracy of computed tomography (CT) and MRI data fusion for MRI-based treatment planning in an institution where an MRI scanner is not available in the radiotherapy department. Methods and Materials The registration inaccuracy of applicators and soft tissue was assessed in 42 applications with CT/MRI data fusion. The absolute positional difference of the center of the applicators was measured in four different planes from the top of the tandem to the cervix. Any inaccuracy of registration of soft tissue in relation to the position of applicators was determined and dose–volume parameters for MRI preplans and for CT/MRI fusion plans with or without target and organs at risk (OAR) adaptation were evaluated. Results We performed 6,132 measurements in 42 CT/MRI image fusions. Median absolute difference of the center of tandem on CT and MRI was 1.1 mm. Median distance between the center of the right ovoid on CT and MRI was 1.7 and 1.9 mm in the laterolateral and anteroposterior direction, respectively. Corresponding values for the left ovoid were 1.6 and 1.8 mm. Rotation of applicators was 3.1°. Median absolute difference in position of applicators in relation to soft tissue was 1.93, 1.50, 1.05, and 0.84 mm in the respective transverse planes, and 1.17, 1.28, 1.27, and 1.17 mm in selected angular directions. The dosimetric parameters for organs at risk on CT/MRI fusion plans without OAR adaptation were significantly impaired whereas the target coverage was not influenced. Planning without target adaptation led to overdosing of the target volume, especially high-risk clinical target volume — D 90 88.2 vs. 83.1 ( p Conclusions MRI-based preplanning with consecutive CT/MRI data fusion can be safe and feasible, with an acceptable inaccuracy of soft tissue registration.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    20
    References
    13
    Citations
    NaN
    KQI
    []