A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses.
2018
OBJECTIVES
The aim of the present review was to compare the outcomes, that is, survival and complication rates of zirconia-ceramic and/or monolithic zirconia implant-supported fixed dental prostheses (FDPs) with metal-ceramic FDPs.
MATERIALS AND METHODS
An electronic MEDLINE search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective cohort studies and retrospective case series on implant-supported FDPs with a mean follow-up of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data extraction was performed independently by two reviewers. Failure and complication rates were analyzed using robust Poisson regression models to obtain summary estimates of 5-year proportions.
RESULTS
The search provided 5,263 titles and 455 abstracts. Full-text analysis was performed for 240 articles resulting in 19 studies on implant FDPs that met the inclusion criteria. The studies reported on 932 metal-ceramic and 175 zirconia-ceramic FDPs. Meta-analysis revealed an estimated 5-year survival rate of 98.7% (95% CI: 96.8%-99.5%) for metal-ceramic implant-supported FDPs, and of 93.0% (95% CI: 90.6%-94.8%) for zirconia-ceramic implant-supported FDPs (p < 0.001). Thirteen studies including 781 metal-ceramic implant-supported FDPs estimated a 5-year rate of ceramic fractures and chippings to be 11.6% compared with a significantly higher (p < 0.001) complication rate for zirconia implant-supported FDPs of 50%, reported in a small study with 13 zirconia implant-supported FDPs. Significantly (p = 0.001) more, that is, 4.1%, of the zirconia-ceramic implant-supported FDPs were lost due to ceramic fractures compared to only 0.2% of the metal-ceramic implant-supported FDPs. Detailed analysis of factors like number of units of the FDPs or location in the jaws was not possible due to heterogeneity of reporting. No studies on monolithic zirconia implant-supported FDPs fulfilled the inclusion criteria of the present review. Furthermore, no conclusive results were found for the aesthetic outcomes of both FDP-types.
CONCLUSION
For implant-supported FDPs, conventionally veneered zirconia should not be considered as material selection of first priority, as pronounced risk for framework fractures and chipping of the zirconia veneering ceramic was observed. Monolithic zirconia may be an interesting alternative, but its clinical medium- to long-term outcomes have not been evaluated yet. Hence, metal ceramics seems to stay the golden standard for implant-supported multiple-unit FDPs.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
42
References
66
Citations
NaN
KQI