Abstract This paper describes the higher cooling capability of the Lockheed Martin coax Micro cryocooler thermal mechanical unit. The design of the previously qualified TRL6 Micro (Nast et al., 2014) [1] was modified to accommodate over twice the input power, greatly increasing the cooling capability. These Micro units are in a split configuration with the cold head separated from the compressor. This unit was optimized for cooling at 105 K and provides cooling over a wide range of temperatures. With a weight below 450 g, this small unit is ideal for compact instruments. Load lines were obtained over a range of powers, cold tip temperatures and rejection temperatures. This testing raised the Technology Readiness Level to six.