Extended range of the Lockheed Martin coax Micro cryocooler

2016 
Abstract This paper describes the higher cooling capability of the Lockheed Martin coax Micro cryocooler thermal mechanical unit. The design of the previously qualified TRL6 Micro (Nast et al., 2014) [1] was modified to accommodate over twice the input power, greatly increasing the cooling capability. These Micro units are in a split configuration with the cold head separated from the compressor. This unit was optimized for cooling at 105 K and provides cooling over a wide range of temperatures. With a weight below 450 g, this small unit is ideal for compact instruments. Load lines were obtained over a range of powers, cold tip temperatures and rejection temperatures. This testing raised the Technology Readiness Level to six.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    5
    Citations
    NaN
    KQI
    []