Interlaboratory assessment of marine bioassays to evaluate the environmental quality of coastal sediments in Spain. II. Bioluminescence inhibition test for rapid sediment toxicity assessment

2006 
El presente trabajo resume el ejercicio interlaboratorio realizado para evaluar la variabilidad del ensayo Microtox® sobre fase solida. El ejercicio se dividio en dos fases consecutivas, cada una de ellas desarrollada sobre seis muestras de sedimento de puertos espanoles. La Fase I incluyo seis laboratorios y se obtuvieron resultados para el protocolo SPT (Solid Phase Test). La Fase II incluyo siete laboratorios y, ademas de obtenerse resultados del protocolo SPT, tres de ellos utilizaron tambien el protocolo para la fase solida BSPT (Basic Solid Phase Test). Si bien se han identificado factores que pueden tener un cierto efecto sobre los resultados, y por lo tanto en la clasificacion de las muestras, los coeficientes de variacion obtenidos pueden considerarse entre los valores normales para ensayos biologicos. Si esto se tiene en cuenta para el analisis de los resultados, especialmente para los de la Fase I, la variabilidad baja considerablemente. El protocolo BSPT obtuvo resultados mas consistentes que el protocolo SPT aun contando solo con los resultados de un numero reducido de laboratorios. La mayor simplicidad del ensayo pudo ser la causa de esta menor variabilidad. The Microtox® bioassay was tested in an interlaboratory study to evaluate the variability when using solid-phase samples. The exercise consisted of two consecutive phases each one carried out with six sediment samples from Spanish ports. Phase I included six laboratories that reported results for the solid-phase test (SPT) protocol, while Phase II included seven laboratories for the SPT protocol and three laboratories for the basic solid-phase test (BSPT) protocol. Even though some interfering factors were identified that could affect the results and sample classification, the coefficients of variation (CV) can be considered in the range for biological tests. When these factors are considered for further assessments, interlaboratory variability is significantly reduced. The BSPT showed lower CV values than the SPT despite the small number of participating laboratories. This better performance may be explained either by the simplicity of the methodology.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    9
    References
    18
    Citations
    NaN
    KQI
    []