ANALYSIS AND MODELING OF PASSIVE DEVICE DEGRADATION FOR THE LONG-TERM ELECTROMAGNETIC EMISSION PREDICTION OF A DC-DC CONVERTER

2015 
Past works showed that the degradation of the passive components caused by aging could induce failures of electronic system, including a harmful evolution of electromagnetic compatibility. This paper presents the impact of the accelerated thermal aging on the electromagnetic emission (EME) of a buck DC-DC converter. The experimental analysis indicates that the aging degradation of several passive components (electrolytic capacitor and powder iron inductor) is the main source of EME evolution. Based on experimental measurement and physical analysis, the empirical degradation models of related passive devices are proposed. The overall objective of this study is to predict the electromagnetic emission evolution of a buck DC-DC converter under a thermal aging, by using these passive device degradation models.