Effect of alternating a-C:H multilayer full coating on fracture behavior of single-crystal silicon-based microstructure in tensile and toughness tests
2021
Abstract The use of alternating hydrogenated amorphous carbon (a-C:H) full coatings on all sides of a single-crystal silicon (SCS) based microstructure was proposed to explore the enhancement of the tensile strength and fracture toughness of a coating−substrate system. By tailoring the individual layer thickness (λ) from 25 to 150 nm, we synthesized a series of multilayer coatings deposited alternately by controlling bias voltage between −200 and −600 V with the total thickness maintained at 300 nm by plasma enhanced chemical vapor deposition (PECVD). The tensile strength and fracture toughness of coating−substrate system were investigated by a quasi-static tensile test and pillar splitting, respectively. A ∼37.8% increase in the tensile strength (maximum of 4.34 GPa) and ∼41.5% increase in the fracture toughness (maximum of 1.33 MPa m1/2) of coated samples were achieved as compared with a bare silicon microstructure. The highest tensile strength was found at a λ of 75 nm, whereas fracture toughness increased monotonically as λ dropped from 150 to 25 nm. We attributed this λ dependence to a combined effect of toughness enhancement and crack shielding. These new findings were useful for the design of alternating multilayer coated micro electro mechanical system (MEMS) devices with enhanced mechanical reliability.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
44
References
0
Citations
NaN
KQI