Study to determine dielectric properties of sandstone, shale, coal, and slate

1976 
Triplicate dielectric constant and loss tangent measurements on samples of sandstone, shale, coal, and slate were performed. Each of the three necessary configurations of the coal material was sampled to obtain measurements, with each sample machined parallel to the coal layering orientation. The coal samples were machined perpendicular to the coal layering and measured. They were conditioned at 100% humidity and at room temperature and remeasured; then conditioned in an elevated environment, and remeasured for dielectric properties. The coal data appear to remain relatively constant over the microwave frequency region. At the Ghz frequencies, the relative dielectric constant of coal is slightly higher for the E-field parallel to the layers than for the perpendicular case. (GRA)