Attenuation of Harmonic Rotor Vibration in a Cage Rotor Induction Machine by a Self-Bearing Force Actuator

2009 
In this paper, attenuation of flexural rotor vibration in electrical machines is considered. In order to generate force on the machine rotor, an electromagnetic actuator based on self-bearing machine working principle is examined. A control method for attenuating harmonic rotor vibration components is applied in a 30 kW two-pole cage induction machine. The machine is equipped with a four-pole supplementary winding for generation of lateral force on the rotor. Experimental results for the two-pole induction motor are presented. The main contribution of this paper is to apply a control method, specially designed for compensating harmonic excitations, by using a built-in electromagnetic actuator in an induction machine.