Determination of Glyphosate and AMPA in Three Representative Agricultural Austrian Soils with a HPLC-MS/MS Method

2013 
We developed a novel method to quantify adsorbed glyphosate and AMPA in soils based on an extraction utilizing Na-tetraborate, an SPE clean-up step, and subsequent LC-MS detection. Reversed phase-based separation of glyphosate and AMPA was realized after FMOC-derivatization. The quantification involved external calibration and 1,2–13C, 15N- labeled glyphosate as well as 13C, 15N labeled AMPA as internal standards. The optimum recovery for extraction was obtained with 40 mM Na-tetraborate. The method was applied in three representative soils (Kirchberg, Phyra, and Pixendorf, Austria) where glyphosate was applied by standard agricultural practices. The recovery for glyphosate extracted with 40 mM Na-tetraborate buffer was 93.5% (RSD <2%) for glyphosate at Kirchberg-cambisol; 95.7% (RSD < 2%) at Pixendorf- chernozem and 79.1% (RSD <7%) at Phyra-stagnosol. The corresponding values for AMPA were 92.4% (RSD <2%) at Kirchberg, 98.1% (RSD <2%) at Pixendorf and 69.9% (RSD <4%) at Phyra. The limits of detection for...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    39
    References
    40
    Citations
    NaN
    KQI
    []