Effect of dialyzate flow on the dialysis adequacy

2011 
Objective To analyze the dialysis adequacy of the maintenance hemodialysis patients under different dialyzate flow.Methods Forty-eight patients under maintenance hemodialysis were divided into four groups according to dialyzate flow:500 ml/min group,600 ml/min group,700 ml/min group and 800 ml/min group,with 12 patients in each group.Each group was treated 6 weeks.The albumin (Alb),hemoglobin(Hb),hematocrit(Hct),blood urea nitrogen (BUN),serum creatinine(SCr) and parathyroid hormone(iPTH) levels before and after treatment were examined,Kt/V and urea reduction ratio(URR) were calculated separately.Results There was no significant difference in Kt/V between 500 ml/min group and 600 ml/min group.Kt/V was no increased when the dialyzate flow rate increased from 500 ml/min to 600 ml/min,that was to say they could not improve the dialysis adequacy.There was statistically significant difference in Kt/V among 500 ml/min group,600 ml/min group,700 ml/min group and 800 ml/min group,and 800 ml/min group on the dialysis adequacy was better.Different dialyzate flow on the impact of the dialysis adequacy was compared in self-control method.Kt/V increased along with the increase of dialyzate flow,and the dialysis adequacy and dialyzate flow showed positive correlation.Conclusion The high dialyzate flow of dialysis treatment can improve Kt/V and has significant effect in enhancing the dialysis adequacy. Key words: Dialysis solutions;  Renal dialysis;  Flow