CALPUFF Model을 이용한 시화공단의 악취관리방안에 관한 연구

2011 
This study was conducted to induce the effective counterplan of odor management in the Sihwa industrial complex(SIC) utilizing to CALPUFF model with sensory odor. The CALPUFF model was applied to simulate a sensory odor, and was evaluated for odor applicability and the distribution status of odor in SIC was predicted. The simulated concentration showed lower than observed concentration but the prediction of odor was so excellent. The simulation result of CALPUFF model for SIC showed that annual mean odor unit was 5∼7 OU/㎥ (min. 3 OU/㎥, max. 25 OU/㎥). The annual mean odor unit in residential area was not high as 1∼3 OU/㎥ but was predicted to be affected by the weather status in the industrial complex. The odor emission sources of high concentration were distributed in the seashore. Therefore the management of the high concentration sources will be further demanded.