Thermal quadrupoles approach for two-dimensional heat flux estimation using infrared and thermocouple measurements on the JET tokamak

2009 
This paper presents several 2D heat flux calculation methods applied to temperature data of one of the most exposed plasma facing components of the JET tokamak. We have two temperature diagnostics: a high time resolution infrared system is used to measure the surface temperature and two embedded thermocouples to measure the temperature in the bulk at 1 cm depth from the surface. A direct calculation is possible using the surface temperature but the presence of thin carbon layers disturb the measurements and leads us to make an inverse computation of the heat flux using the thermocouple data.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    13
    References
    31
    Citations
    NaN
    KQI
    []