A Comparison of Recognition Performances in Speech-Spectrum Noise by Listeners with Normal Hearing on PB-50, CID W-22, NU-6, W-1 Spondaic Words, and Monosyllabic Digits Spoken by the Same Speaker

2008 
Background: So that portions of the classic Miller, Heise, and Lichten (1951) study could be replicated, new recorded versions of the words and digits were made because none of the three common monosyllabic word lists (PAL PB-50, CID W-22, and NU–6) contained the 9 monosyllabic digits (1–10, excluding 7) that were used by Miller et al. It is well established that different psychometric characteristics have been observed for different lists and even for the same materials spoken by different speakers. The decision was made to record four lists of each of the three monosyllabic word sets, the monosyllabic digits not included in the three sets of word lists, and the CID W-1 spondaic words. A professional female speaker with a General American dialect recorded the materials during four recording sessions within a 2-week interval. The recording order of the 582 words was random. Purpose: To determine—on listeners with normal hearing—the psychometric properties of the five speech materials presented in speech-spectrum noise.