A Modified Wavenumber Algorithm of Multi-Layered Structures with Oblique Incidence Based on Full-Matrix Capture
2021
Full-matrix capture (FMC)-based ultrasonic imaging provides good sensitivity to small defects in non-destructive testing and has gradually become a mainstream research topic. Many corresponding algorithms have been developed, e.g., the total focusing method (TFM). However, the efficiency of the TFM is limited, especially in multi-layered structures. Although the appearance of wavenumber algorithms, such as extended phase-shift migration (EPSM) methods, has improved imaging efficiency, these methods cannot be applied to cases with oblique incidence. Therefore, a modified wavenumber method for full-matrix imaging of multi-layered structures with oblique array incidence is proposed. This method performs a coordinate rotation in the frequency domain to adapt it to the oblique incidence. It then utilizes wave-field extrapolation to migrate the transmitting and receiving wave field to each imaging line, and a correlation imaging condition is used to reconstruct a total focused image. The proposed method can deal with any incident angle without precision loss. Moreover, it inherits the computational efficiency advantages of the wavenumber algorithms. The simulation and experimental results show that the proposed method performs better in terms of accuracy and efficiency than the TFM. Specifically, it is nearly 60 times faster than the TFM when processing an FMC dataset with a size of 4096 × 64 × 64.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader