Cryogenic‐related Performance of an SRF Cavity Module in NSRRC

2006 
A superconducting 500‐MHz cavity module has been installed into the electron storage ring of NSRRC. This SRF module is tested on both the RF and cryogenic performances, before and after installation into the electron ring. Calibrations and measurements on its cryogenic load at different operating helium bath pressures are described and concluded. The test results of unloaded quality factor are reported. Meanwhile the excellent regulation on helium bath pressure is so advantageous to all these measurements. During normal operation with RF power, fluctuations of the helium bath pressure and liquid helium level are +/− 1.38 mbar (0.02 psi) and +/−0.2%, respectively.