Fast Initial Rotor Position Estimation for IPMSM with Unipolar Sequence-Pulse Injection
2021
The square-wave voltage signal injection method with the proportional-integral (PI) observer is commonly adopted to estimate the rotor position of interior permanent magnet synchronous motor (IPMSM). However, the saliency estimation method with PI observer is a continuous injection method and the polarity identification method is a discrete one, which causes extra transition time and complexity. To solve this problem, a fast unipolar sequence-pulse injection method is proposed to unify the process of saliency and polarity identification and the complexity of the algorithm as well as the identification time are reduced. At the same time, a four-stage search algorithm is proposed to ensure the fast convergence and improve the accuracy by reducing the number of the pulse voltage signals. The experiment on motor drive platform verifies the effectiveness of the proposed method to IPMSMs with different saliency ratios.