Late Pseudoaneurysm After Access Site Closure with Manta in Transfemoral Aortic Valve Implantation

2019 
Introduction Access site vascular complications in transfemoral transcatheter aortic valve implantation (TF-TAVI) are still a major concern. Recently, a novel collagen plug based closure device (Manta) was introduced. The results from the first reports on Manta are very promising, but not much is known about the long-term patency. Report A case of late pseudoaneurysm after access site arterial closure with Manta in TF-TAVI is described. The patient presented five weeks after left sided TF-TAVI with pain and claudication like symptoms in the left leg. CT angiography revealed a pseudoaneurysm at the puncture site. The patient was successfully treated by vascular surgery. Discussion The results from recent peri-operative reports on the Manta vascular closure device (VCD) are promising, but not much is known about the long-term patency. In the present report a patient is described who developed a pseudoaneurysm several weeks after access site closure with Manta. To the authors' knowledge, no such late access site complications after use of the Manta VCD have been reported previously.