Investigation of space passive hydrogen maser atomic beam formation system life-time
2014
For SPHM life-time the most critical part is atomic beam formation system. Two special set-ups were made to evaluate necessary amount of hydrogen in H2-source and ability of evacuation system to absorb required amount of hydrogen. The experiment has shown that both systems restrict SPHM life time with a period of more than 15 years.