Analysis of SBO ATWS for Maanshan PWR

2015 
Abstract Station blackout anticipated transient without scram (SBO ATWS) is considered as loss of off-site and on-site power but no credit for automatic reactor trip. SBO ATWS causes reactor coolant pump (RCP) trip, loss of all main feedwater pumps and turbine trip, then the reactor coolant system (RCS) pressure rises rapidly due to loss of heat removal paths. The ASME Code Level C service limit criteria of 22.06 MPa (3200 psig) is assumed to be an unacceptable plant condition in SECY-83-293. The simulation is performed by TRACE which is a thermal-hydraulic code developed by U.S. NRC. Three different AFW flows are modeled to ensure the pressures will not be beyond the criteria. RCP seal-leakage is concerned as a SBLOCA due to loss of RCP seal-cooling. Four possible leakage flows are modeled to examine the reactor core water level and temperature variation.