Evaluation of dose received by workers while repairing a failed spent resin mixture treatment device

2021 
Abstract Intermediate-level radioactive waste (ILW) is not subject to legal approval for cave disposal in Korea. To solve this problem, a spent resin treatment device that separates 14C-containing resin from zeolite/activated carbon and desorbs 14C through a microwave device has been developed. In this study, we evaluated the radiological safety of the operators performing repair work in the event of a failure in such a device treating 1 ton of spent resin mixture per day. Based on the safety evaluation results, it is possible to formulate a design plan that can ensure the safety of workers while developing a commercialized device. When each component of the resin treatment device can be repaired from the outside, the maximum and minimum allowable repair times are calculated as 263.2 h and 27.7 h for the 14C-detached resin storage tank and zeolite/activated carbon storage tank, respectively. For at least 6 h per quarter, the worker's annual dose limit remains within 50 mSv/year; further, over 5 years, it remained within 100 mSv. At least 6 h of repair time per quarter is considered, under conservative conditions, to verify the radiological safety of the worker during repair work within that time.