International Intercomparison of Electric-Field Strength at 100 MHz

1983 
This paper discusses an international intercomparison of electric field strength at 100 MHz. Laboratories in four countries participated in the intercomparison. Measurements from each of the laboratories fell within a range of +0.75 to -0.5 dB with respect to the overall average. The transfer standard used in the measurement is described and the details of the results are presented.