Biliary hemostasis using an endoscopic plastic stent placement for uncontrolled hemobilia caused by transpapillary forceps biopsy (with video)

2016 
A 78-year-old woman was referred to our hospital for the examination and treatment of jaundice. A transpapillary forceps biopsy for a long distal bile duct stricture was performed using endoscopic retrograde cholangiopancreatography. Immediately after the biopsy, massive bleeding was observed from the orifice of the papilla. Although hemobilia was pulsatile, an endoscopic biliary plastic stent placement was very effective in achieving hemostasis. However, a nasal biliary catheter was required because a blood clot clogged the stent on the following day. Although covered self-expandable metal stent (CSEMS) placement has been reported for achieving endoscopic hemostasis for bleeding, we chose to use a plastic stent to reduce the risk of post-procedure pancreatitis. The placement of both an endoscopic biliary plastic stent and a nasobiliary drainage catheter can be an alternative hemostatic tool to CSEMSs.