The facility at Fermilab was used to develop, fabricate, and commission an RF gun for the TeSLA Test Facility Linac. A time dependence is observed in the photo-emission and field emission from the photo-injector at Fermilab. The focussing solenoids can be adjusted to cause the QE and dark current to increase or decrease with time. The observed variation is in excess of a factor of 5 in the QE and a factor of 10 in the dark current, with time constants measured in hours. The evidence suggests that the source of the time-dependent behaviour is the Cs/sub 2/Te cathode.