Value of Spectral Detector Computed Tomography to differentiate Infected from Noninfected Thoracoabominal Fluid Collections

2021 
Abstract Purpose To investigate the diagnostic value of spectral detector CT (SDCT)-derived virtual non-contrast (VNC), virtual monoenergetic images (VMI) and iodine overlays (IO) for distinguishing infected from noninfected fluid collections (FC) in the chest or abdomen. Method This retrospective study included 58 patients with venous phase SDCT with 77 FC. For all included FC, microbiological analysis of aspirated fluid served as reference. For quantitative analysis, wall thickness was measured, and (ROI)-based analysis performed within the fluid, the FC’s wall (if any) and the aorta. Two radiologists qualitatively evaluated visibility of wall enhancement, diagnostic confidence regarding infection of fluid collection, confidence of CT-guided drainage catheter placement and visibility of anatomical landmarks in conventional images (CI) and VNC, VMI40keV, IO. Results Wall thickness significantly differed between infected (n=46) and noninfected (n=31) FC (3.5±1.8mm vs. 1.4±1.8mm, AUC=0.81; p Conclusion Spectral reconstructions improve the assessment of infected from noninfected thoracoabdominal fluid collections and depiction of wall enhancement. Diagnostic performance of the quantitative measurements in spectral reconstructions were comparable with measurements in conventional images.