The effect of flow on blood oxygen level dependent (R2*) MRI of orthotopic lung tumors

2019 
PURPOSE: Blood oxygen level dependent (BOLD) MRI based on R2* measurements can provide insights into tumor vascular oxygenation. However, measurements are susceptible to blood flow, which may vary accompanying a hyperoxic gas challenge. We investigated flow sensitivity by comparing R2* measurements with and without flow suppression (fs) in 2 orthotopic lung xenograft tumor models. METHODS: H460 (n = 20) and A549 (n = 20) human lung tumor xenografts were induced by surgical implantation of cancer cells in the right lung of nude rats. MRI was performed at 4.7T after tumors reached 5 to 8 mm in diameter. A multiecho gradient echo MRI sequence was acquired with and without spatial saturation bands on each side of the imaging plane to evaluate the effect of flow on R2* . fs and non-fs R2* MRI measurements were interleaved during an oxygen breathing challenge (from air to 100% O2 ). T2* -weighted signal intensity changes (ΔSI(%)) and R2* measurements were obtained for regions of interest and on a voxel-by-voxel basis and discrepancies quantified with Bland-Altman analysis. RESULTS: Flow suppression affected ΔSI(%) and R2* measurements in each tumor model. Average discrepancy and limits of agreement from Bland-Altman analyses revealed greater flow-related bias in A549 than H460. CONCLUSION: The effect of flow on R2* , and hence BOLD, was tumor model dependent with measurements being more sensitive in well-perfused A549 tumors.