Lung Ultrasound in Acute Heart Failure
2019
Abstract Objectives This study sought to assess the prevalence, changes in, and prognostic importance of B-lines, a pulmonary congestion measure by using a simplified lung ultrasonography (LUS) method in acute heart failure (AHF). Background Pulmonary congestion is an important finding in AHF, but conventional methods for its detection are insensitive. Methods In a 2-site, prospective, observational study, 4-zone LUS was performed early during hospitalization for AHF (LUS1) and at discharge (LUS2). B-lines were quantified off-line, blinded to clinical findings and outcomes, by a core laboratory. Results Among 349 patients (median, 75 years of age; 59% men; mean ejection fraction 39%), the sum of B-lines in 4 zones ranged from 0 to 18 (LUS1). The risk of an adverse in-hospital event increased with rising number of B-lines on LUS1: the odds ratio for each B-line tertile was 1.82 (95% confidence interval [CI]: 1.14 to 2.88; p = 0.011). B-line count decreased from a median of 6 (LUS1) to 4 (LUS2; p Conclusions Pulmonary congestion using a simplified 4-zone LUS method was common in patients with AHF and improved with therapy. A higher number of B-lines at baseline and discharge identified patients at increased risk for adverse events.