Improve retained dose and impact energy of inner surface plasma immersion ion implantation using long pulse duration with deflecting electric field
2002
Not restricted by the line-of-sight process, plasma immersion ion implantation (PIII) has shown great potential for inner surface modification, but the impact energy and retained dose turned to be very low. The process was investigated numerically and experimentally in this paper. The results show that a high percentage of low impact energy ions was the key factor that resulted in low impact energy on the inner surface. This was caused by sheath overlapping and appearance of the dead zone during inner surface PIII. Long pulse duration could alleviate this problem and increase ion impact energy on the inner surface, hence the implant depth, which was key factor for the modifying effect of PIII. Also, long pulse duration was helpful in improving the retained dose on the inner surface.